Select |
Mfr Part # |
Price |
Stock ? |
Manufacturer |
Min order |
RoHS status |
Seri |
Package |
Part Status |
Datasheet |
Delay Time |
Output Type |
Mounting Type |
Circuit |
Type |
Voltage - Supply |
Contact Rating @ Voltage |
Trip Status |
Trip Range |
|
3UG46162CR20
VOLTAGE MONITORING RELAY
|
Contact |
0 - immediate |
Siemens |
1 |
ROHS3 Compliant |
SIRIUS |
Box |
Active |
Datasheet
|
0.1 Sec ~ 20 Sec | Relay | DIN Rail | SPDT (1 Form C) | Voltage Asymmetry, Voltage Sensing AC, Phase Loss, Phase Sequence | 400VAC | 3A @ 400VAC | - | 90 ~ 400V AC |
|
SLD-440-ALE
PHASE MONITOR RELAY
|
Contact |
0 - immediate |
Mueller Electric Co |
1 |
Request inventory verification |
SLD |
Box |
Discontinued at Digi-Key |
Datasheet
|
0.03 Sec ~ 20 Sec | Relay | Chassis Mount | DPDT (2 Form C) | Phase Loss, Phase Sequence, Voltage Sensing AC | 440 ~ 480VAC | 3A @ 600VAC | Energized High/Low | 370 ~ 460V AC |
|
VBA-24-DLA
VBA SERIES SINGLE PHASE MONITORI
|
Contact |
0 - immediate |
ATC-Diversified Electronics |
1 |
RoHS non-compliant |
VBA |
Box |
Active |
Datasheet
|
0.05 Sec ~ 0.5 Sec | Relay | Socketable | DPDT (2 Form C) | Voltage Sensing AC | 24VDC | 5A @ 240VAC | Energized High/Low | 19 ~ 29V DC |
|
2495690000
ACT20P-UI-2RCO-AC-P
|
Contact |
0 - immediate |
Weidmüller |
1 |
unknown |
ACT20P |
Box |
Active |
Datasheet
|
0 Sec ~ 99 Sec | Relay | DIN Rail | DPDT (2 Form C) | Process Sensing | 90 ~ 264VAC | 6A @ 250VAC/110VDC | Energized High/Low | - |
|
3UG46511AA30
DIGITAL MONITORING RELAY
|
Contact |
0 - immediate |
Siemens |
1 |
ROHS3 Compliant |
SIRIUS |
Box |
Active |
Datasheet
|
0.1 Sec ~ 99.9 Sec | Relay | DIN Rail | SPDT (1 Form C) | Speed Monitoring | 24VAC/DC | 3A @ 250VAC | - | 50 ~ 60Hz |
|
7940017849
PROCESS MONITORING
|
Contact |
0 - immediate |
Weidmüller |
1 |
RoHS Compliant |
DPA |
Bulk |
Obsolete |
Datasheet
|
- | Relay | DIN Rail | SPDT (1 Form C) x 2 | Voltage Sensing DC | 24VDC | - | Energized High/Low | 0 ~ 100mV DC |
|
7940017848
SIGNAL CONVERTER/DISCONNECTOR
|
Contact |
0 - immediate |
Weidmüller |
1 |
RoHS Compliant |
DPA |
Bulk |
Obsolete |
Datasheet
|
- | Relay | DIN Rail | SPDT (1 Form C) x 2 | Voltage Sensing DC | 24VDC | - | Energized High/Low | 0 ~ 10mV DC |
|
7940017847
PROCESS MONITORING
|
Contact |
0 - immediate |
Weidmüller |
1 |
RoHS Compliant |
DPA |
Bulk |
Obsolete |
Datasheet
|
No Delay | Relay | DIN Rail | SPDT (1 Form C) x 2 | Voltage Sensing AC | 24VDC | - | - | 0 ~ 125V AC |
|
7940012970
SIGNAL CONVERTER/DISCONNECTOR
|
Contact |
0 - immediate |
Weidmüller |
1 |
RoHS Compliant |
DPA |
Bulk |
Obsolete |
Datasheet
|
- | Relay | DIN Rail | SPDT (1 Form C) x 2 | Voltage Sensing DC | 24VDC | - | Energized High/Low | 0 ~ 10V |
|
7940011718
DPADCV 0-10V SIGNAL CONV/DISCON
|
Contact |
0 - immediate |
Weidmüller |
1 |
RoHS Compliant |
DPA |
Bulk |
Obsolete |
Datasheet
|
- | Relay | DIN Rail | SPDT (1 Form C) x 2 | Voltage Sensing DC | 24VDC | - | - | 0 ~ 10V |
|
SLD-230-ASA
SLD SERIES PHASE AND UNDER-VOLTA
|
Contact |
0 - immediate |
ATC-Diversified Electronics |
1 |
RoHS non-compliant |
SLD |
Box |
Active |
Datasheet
|
0.03 Sec ~ 20 Sec | Relay | Socketable | SPDT (1 Form C) | Phase Loss, Phase Sequence, Voltage Sensing AC | 208 ~ 240VAC | 10A @ 240VAC | Energized High/Low | 185 ~ 230V AC |
|
3UG46512AW30
DIGITAL MONITORING RELAY
|
Contact |
0 - immediate |
Siemens |
1 |
ROHS3 Compliant |
SIRIUS |
Box |
Active |
Datasheet
|
0.1 Sec ~ 99.9 Sec | Relay | DIN Rail | SPDT (1 Form C) | Speed Monitoring | 24 ~ 240VAC/DC | 3A @ 250VAC | - | 50 ~ 60Hz |
|
WVM911AH
3 PHASE VOLTAGE MONITOR
|
Contact |
0 - immediate |
Littelfuse Inc. |
1 |
ROHS3 Compliant |
WVM |
Bulk |
Obsolete |
Datasheet
|
0.25 Sec ~ 30 Sec | Relay | Chassis Mount | SPDT (1 Form C) | Voltage Sensing AC, Phase Loss | 400 ~ 480VAC | 10A @ 250VAC | Energized High/Low | 400 ~ 480V AC |
|
SLD-380-ASA
SLD SERIES PHASE AND UNDER-VOLTA
|
Contact |
0 - immediate |
ATC-Diversified Electronics |
1 |
RoHS non-compliant |
SLD |
Box |
Active |
Datasheet
|
0.03 Sec ~ 20 Sec | Relay | Socketable | SPDT (1 Form C) | Phase Loss, Phase Sequence, Voltage Sensing AC | 380VAC | 10A @ 240VAC | Energized High/Low | 315 ~ 390V AC |
|
3UG45811AW30
INSULATION MONITORING RELAY, 400
|
Contact |
0 - immediate |
Siemens |
1 |
ROHS3 Compliant |
SIRIUS |
Box |
Active |
Datasheet
|
- | Relay | DIN Rail | SPDT (1 Form C) | Insulation Monitoring | 24 ~ 240VAC/DC | - | - | 0 ~ 400V AC |